Adjusting the voltage to the optimum setting for the transformer extends the service life of the halogen bulbs
Input and output-end screw connection terminals with strain relief
During normal mains overvoltage, the nominal voltage of the halogen bulbs is not exceeded
Integrated fuse protection and temperature limiter serve as protection in the event of short-circuit and overload
Easy to use, even where the fire behaviour of the building material (wood, furniture, internal ceilings) is unknown
Short-circuit proof safety transformers in cast resin, fully encapsulated to supply 12 V halogen bulbs
Test voltage: | Between input and output circuits 5000 V, 50 Hz |
Short-circuit proof: | Conditionally short-circuit proof (no fuse protection required) |
Design: | Encapsulated in the insulation housing |
Protection class | II |
Protection rating: | IP40 housing |
Connection leads: | IP 00W (HIT 60/L and HIT 105/L) |
Ambient temperature: | 40°C |
Insulation category: | A (of the insulation system) |
Input voltage: | 230 V |
With special transformer dimmer suitable for adjusting brightness | |
Frequency: | 50 Hz to 60 Hz |
Output voltage: | 11.5 V at full load |
Leads: | PRI: screw connection terminals or mains connection cable, 2 m long |
SEC: screw connection terminals or cables, approximately 1 m long with wire end ferrules | |
Mounting: | Can be mounted via perforations in the clamp connection boxes |
Colour: | White |
VDE 0570 part 2-6, IEC 61558-2-6, DIN EN 61558-2-6