Switch mode triple output AC/DC embedded power supplies with a low safety ground leakage current and medical and ITE approval. These switch mode AC/DC power supplies have a universal AC input, triple output voltage, a built in EMI filter and dual AC fuses . The footprint for these AC/DC power supplies is 2" x 4" with a height of less than 1U. Suitable applications for these embedded AC/DC power supplies include information technology equipment (ITE) and light industrial systems, as well as for equipment intended for non-patient contact and non-patient critical use in low power medical, dental and laboratory applications.
Worldwide IT equipment (ITE) approval
Class I approved , Class II approved (with Class A EMI)
Universal AC input
Overload and overvoltage protection
Built in EMI filter (CISPR 22 Class B)
Safety ground leakage current of 275ua @ 50/60 Hz; 264 VAC input
EMI compliance: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted, VDE0878PT3 Class B conducted
Harmonic Current compliance: EN61000-3-2
Additional Data | ||||
Output Voltage | Minimum Load | Maximum Load with Convection Cooling | Maximum Load with 30CFM Forced Air | Peak Load |
+ 5V | 0.5 A | 5 A | 8 A | 9 A |
+ 12V | 0.1 A | 2.5 A | 3 A | 4 A |
- 12V | 0 A | 0.5 A | 0.7 A | 0.7 A |
Mating connectors for AC input connectors see stock numbers 173-3076 and 679-4723. For DC output connectors see stock numbers 173-3105 and 679-4723
Derate output at 2.5% per degree from 50° to 80°C
UL, TUV, CB, CCC
TUV: 60950, 60601-1, 3rd edition, UL: 60950, 60601-1, CSA: 60950, 60601-1, CB: Certificate and report 3rd edition, CE: Mark (LVD), CQC: Mark
![]() |